The genset’s range is 9 – 2058 kVA
The Gensets can be open type or canopied (for outside work in all conditions). The canopy reduces noise as well up to 70-75 dB at 1 m from the engine. The Gensets can be also fixed or mobile in several types of trailer.
Used engines:
- PERKINS
- JOHN DEERE
- VOLVO
- DEUTZ
- CUMMINS
- NEW HOLLAND
- RICARDO
Options:
- ATS and AMF
- Power panel
- Heating system for quick start in low ambient temperatures
- Fuel level in %
- 4-steps automatic fuel filling
- Fuel reserve
- Max generator current
- High oil temperature
- High/low oil level
- High generator temperature
- Programmed analogue and digital tasks
- Electronic card with 20 alarms
- Measuring set (kW, kVA, kVAr, kWh, cos φ)
- Mufflers
- Bigger fuel tank
- Additional fuel tank
- Heater against generator condensation
- Remote control
A/ DIESEL GENSETS
|
Type |
Engine |
Generator |
Pn |
Pmax |
|
P 9 M° |
403C-11G |
ECO3-1L |
9,1 |
10,0 |
|
P 14 M° |
403C-15G |
ECO3-2L |
13,3 |
14,5 |
|
P 21 M° |
404C-22G |
ECO281L |
20,0 |
22,0 |
|
P 27 M |
31524 |
MJB160MA4 |
27,0 |
30,0 |
|
P 30 M |
1103A-33G |
MJB160MB4 |
30,0 |
33,0 |
|
P 40 M |
1004G |
MJB200SB4 |
42,5 |
47,0 |
|
P 41 M |
1103A-33TG1 |
MJB200SB4 |
42,5 |
47,0 |
|
P 60 M |
1004TG1 |
MJB200MB4 |
63,0 |
70,0 |
|
P 65 M |
1103A-33TG2 |
MJB200MB4 |
60,0 |
66,0 |
|
P 75 M |
1004TG2 |
MJB225SA4 |
75,0 |
82,5 |
|
P 80 M |
1104A-44TG2 |
MJB225SB4 |
80,0 |
88,0 |
|
P 105 M |
1104C-44TAG2 |
MJB225MA4 |
100,0 |
110,0 |
|
P 130 M |
1006TAG |
MJB250MA4 |
136,0 |
150,0 |
|
P 155 M |
1006TAG2 |
MJB250MA4 |
150,0 |
165,0 |
|
P 210 M |
1306CE87TAG3 |
MJB250LA4 |
208,0 |
229,0 |
|
P 230 M |
1306CE87TAG4 |
MJB250LB4 |
228,0 |
250,0 |
|
P 245 M |
1306CE87TAG6 |
MJB250LB4 |
250,0 |
275,0 |
|
P 305 M |
2306CE14TAG2 |
MJB315SA4 |
300,0 |
330,0 |
|
P 355 M |
2306CE14TAG2 |
MJB315SB4 |
350,0 |
380,0 |
|
P 405 M |
2306CE14TAG3 |
MJB315MA4 |
400,0 |
440,0 |
|
P 455 M |
2806CE16TAG1 |
MJB315MB4 |
450,0 |
500,0 |
|
P 505 M |
2806CE16TAG2 |
MJB355SA4 |
500,0 |
550,0 |
|
P 635 M |
2806CE18TAG2 |
MJB355MA4 |
635,0 |
700,0 |
|
P 730 U |
4006TAG2 |
MJB400MA4 |
730,0 |
800,0 |
|
P 805 U |
4006TAG3 |
MJB400MA4 |
800,0 |
900,0 |
|
P 1050 U |
4008TAG2 |
MJB400MB4 |
1022,0 |
1125,0 |
|
P 1280 U |
4012TWG2 |
MJB400LB4 |
1240,0 |
1370,0 |
|
P 1550 U°° |
4012TWG2 |
PI734C |
1505,0 |
1656,0 |
|
P 1760 U°° |
4016TWG2 |
PI734D |
1650,0 |
1815,0 |
|
P 2060 U°° |
4016TAG2 |
PI734F |
2058,0 |
2263,0 |
B/ NATURAL GAS GENSETS
| Type | Рnom (kVA) | Pnom (kW) | Pmax (kVA) | Pmax (kW) | Consumption (нm3/h) |
| ESG 6 | 6 | 4,8 | 8 | 6,4 | 3,3 |
| ESG 8 | 8 | 6,4 | 10 | 8 | 4,2 |
| ESG 12,5 | 12,5 | 10 | 14 | 11,2 | 6,5 |
| ESG 15,5 | 15,5 | 12,4 | 17 | 13,6 | 6,6 |
| ESG 22 | 22 | 18 | 25 | 20 | 7,5 |
| ESG 36 | 36 | 29 | 40 | 32 | 11 |
| ESG 56 | 56 | 45 | 62 | 50 | 17 |
| ESG 72 | 72 | 58 | 82 | 65 | 24,5 |
| ESG 90 | 90 | 72 | 100 | 80 | 28 |